Intermec EasyCoder C4 Programmers Guide Ed. 3 31
Chapter 7 Commands
Remarks, cont.
Set the Form Step Value p
4
to +3 for the counter Cn used in our example (see the
C-command line). Also refer to C Command Counter.
FK"TEST3"
FS"TEST3"
C0,6,L,+3,"Counter 0"
B120,50,0,2,3,6,100,B,C0
B320,50,0,2,3,6,100,B,C0+1
B520,50,0,2,3,6,100,B,C0+2
FE