Goodrive200 inverters Function codes
104
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
Setting range:0.0~100.0%
P09.09
O
utput upper
limit of PID
100.0%
P09.10
O
utput lower
limit of PID
These parameters are
used to set the upper and
lower limit of the PID adjustor output.
100.0 % corresponds to Max. Frequency
or the Max.
Voltage of ( P04.31)
Setting range of P09.09: P09.10~100.0%
Setting range of P09.10: -100.0%~P09.09
0.0%
P09.11
Feedback
offline
detection
value
0.0%
P09.12
Feedback
offline
detection
time
Set the PID feedback
offline detection value, when
the detection value is smaller than or equal to the
feedback offline detection value, and the
lasting time
exceeds the set value in P09.12
, the inverter will
report “PID feedback offline fault”
and the keypad will
display PIDE.
Setting range of P09.11: 0.0~100.0%
Setting range of P09.12: 0.0~3600.0s
1.0s
P09.13
PID
adjustment
0x00~0x11
LED ones: