Goodrive200 inverters Function codes
Name
Detailed instruction of parameters
Default
value
B frequency
command
reference
0:Maximum output frequency, 100% of
B frequency setting corresponds to the maximum
A frequency command, 100% of B frequency
setting corresponds to the maximum
frequency. Select this setting if it needs to adjust on
the base of A frequency command.
0 ○
P00.09
0: A, the current frequency setting is A freauency
1: B, the current frequency setting is B frequency
2: A+B, the current frequency setting is A frequency
command + B frequency command
3: A-
B, the current frequency setting is A frequency
command - B frequency command
4: Max(A, B):
The bigger one between A frequency
command and B frequency is the set frequency.
5: Min(A, B):
The lower one between A frequency
command and B frequency is the set frequency.
Note:The combination manner can be
P05(terminal function)
0 ○
P00.10
When A and B frequency commands are selected as
this parameter will be the initial
value of inverter reference frequency
Setting range:0.00 Hz~P00.03(the Max. frequency)
e means the time needed if the inverter
speeds up from 0Hz to the Max. One (P00.03).
DEC time means the time needed if the inverter
speeds down from the Max. Output frequency to 0Hz
series inverters define four groups of