Goodrive300-21 integrated machine for air compressor Communication protocol
-103-
BIT0:=1 Clear the working time of part 1
=0 invalid
BIT1:=1 Clear the working time of part 2
=0 invalid
BIT2:=1 Clear the working time of part 3
=0 invalid
BIT3:=1 Clear the working time of part 4
=0 invalid
BIT4:=1 Clear the working time of part 5
=0 invalid
BIT5:=1 Clear the working time of the device
=0 invalid
BIT6:=1 Solenoid valve loading
=0 Solenoid valve unloading
Maintenance set time of part 1,
range: 0–65535
Maintenance set time of part 2,
range: 0–65535
Maintenance set time of part 3,
range: 0–65535
Maintenance set time of part 4,
range: 0–65535
Maintenance set time of part 5,
range: 0–65535
Working time of part 1; 0–65535
Working time of part 2; 0–65535
Working time of part 3; 0–65535
Working time of part 4; 0–65535
Working time of part 5; 0–65535
Running time of the device; 0–65535
Command reference during fan debugging
mode
0: No action
1: Run
2: Jogging
3: Stop
4: Coast to stop
5: Reset faults