IPETRONIK PlugIn X V02.14.00
IPETRONIK GmbH & Co. KG
15/ 87
2.7 CAN ID range notification
A warning message is added to channels with a manually configured CAN ID in the range of 0x0280 ...
0x02FF. Since this range is being reserved for communication by IPETRONIK measurement devices,
configuring these for measurement messages leads to problems in the general communication
(measurement start, stop, detection, initialisation and resetting).
However, if such IDs are configured, a CANdb measurement with e.g. the IPEmotion PlugIn Protocols is
possible (a device restart might be needed).
2.8 Resetting Sensor Excitation after Change of Sensor Mode
If the sensor mode of a channel has been changed, the sensor excitation (if supported) is automatically
changed to 0 V.This is done to prevent sensors from potential damage.
Note that there are some channels and sensor modes with a fix sensor excitation. If the sensor mode is
changed to such mode (e.g. EIPE) or on such channel (e.g. channels 1-20 of a M-SENS 24), the specific
sensor excitation is applied as has been before.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IPETRONIK IPEmotion PlugIn IPETRONIK-X and is the answer not in the manual?

IPETRONIK IPEmotion PlugIn IPETRONIK-X Specifications

General IconGeneral
BrandIPETRONIK
ModelIPEmotion PlugIn IPETRONIK-X
CategoryMeasuring Instruments
LanguageEnglish