X-LINK modules
IPETRONIK PlugIn X V02.14.00
IPETRONIK GmbH & Co. KG
31/ 87
3.4.4 Channel LED indication
Channel LED
Meaning
Device start up, channel inactive
Off
Identification of the selected channel during configuration.
Yellow 1 Hz flashing
Waiting for user action!
Sensor has been pluged in, but
channel has not been initialized resp. channel is still inactive
Yellow continuous
OK - Signal measurement is running. (Sensor connected)
Green continuous
Error - source of fault could be:
- over-current on excitation detected
- sensor break or bridge break detected
- counter overflow
- general hardware error
Red 1 Hz flashing
No sensor pluged in although channel is active