Chapter 6 SETUP MODE
6-92 UNI-3 Service Manual
Dot display
Segment display
Setting value
*ZERO PRIC 1 B18-01-01 0 ZERO PRIC 1
Select processing when amount is 0
yen
1:BAR 0/No amount
2:NO. BAR/Amount 0
3:
NO PRICE/No amount
*ERROR TARE -1:NO B18-01-02 ERROR TARE
1
Tare error display
1:NO 2:YES
*ERROR ZERO PRICE 2:YES B18-01-03 ERR 0 PRICE 2 Amount 0 yen error detect
1:NO 2:YES
*NO POS ERR -1:NO DISP B18-02-01 NO POS ERR 1 POS code set Error
1:NO DISP,2:NO PRNT,3:NO BAR
1: No error display
2: No label print
3: No barcode print
*DMG THER ERR -2:CONTI B18-03-01 THERMAL ERR 2 Thermal head empty error detect
1:ONE TIME,2:CONTI,3:NO MESG
1: Detect first time
2: Detect each time
3: No error message
Setting for customization of UNI-3 error detection method
Items for which error detection is not required can be made to continuously operate by selecting No Error
Detection.