Chapter 7 ADJUSTMENT MODE
UNI-3 Service Manual 7-51
C08-03 AREA SETTING
The dot display
The segment display
Setting of the weight acceleration :
Set the weight acceleration of the designation area after removing the protection to make A/D board store the
information.
Available only for the A/D board incorporated on UNI-7.
For P-930 with the external weighing device, the weight acceleration is fixed.