Chapter 7 ADJUSTMENT MODE
7-26 UNI-3 Service Manual
C07-01-08 THE CHECKING OF HEATER'S BEING BROKEN
The dot display
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
*
H
E
A
D
T
E
M
P
R
I
S
E
P
R
T
0
:
N
O
The segment display
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
C
0
7
-
0
1
-
0
8
P
R
O
T
E
C
T
0
Sub cursor: Toggle back and forth between •0• and •1• by pressing the •’ key.
Return to the guidance display by entering the setting value or pressing the [CLR] key.
0: NO
1: YES
Selects whether to execute the malfunction check of the heater.
Execute the malfunction check of the heater: YES
Not execute the malfunction check of the heater: NO
Default: 0 : NO