EasyManua.ls Logo

Janome JR3300 series - Input Signal (PNP)

Janome JR3300 series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
External Control (I/O / Fieldbus) 104 DESKTOP ROBOT JR3000
8.9
Input Signal (PNP)
When using an external power supply
Input signals are treated as active when the photocoupler is ON.
When using an external power supply, the input signals become active if the input pin and the
external power supply are ON.
When using an internal power supply (optional)
Input signals are treated as active when the photocoupler is ON.
When using an internal power supply, the input signals become active if the input pin and the
COM+ pin are ON.
If connecting a two-wire external device, such as a sensor, use one which has a leakage current
of no more than 0.3 mA. If you use a device with a leakage current of more than 0.3 mA, it may
not turn OFF.
Caution
Do not assign wiring other than the wiring specified above.
Assigning the wrong wiring can damage the internal circuits.
#sysIn1-
#sysIn8
COM-
(GND)
2.4K
External Power Supply DC 24 V
#sysIn1-
#sysIn8
COM+
(DC 24 V)
2.4K
Internal Power Supply DC 24 V

Table of Contents

Related product manuals