External Control (I/O / Fieldbus) 80  DESKTOP ROBOT JR3000
7.6.6 
Settings
Settable Items
Setting Range / 
Selection
Function
Word Count for 
Read/Write Domain
8
16
32
64
127
Select the number of words to use in the Fieldbus 
read/write domain.
The read/write domain makes the same number of 
words available.
Toggle DAP2 
Support
Invalid
Valid
Specify whether or not your module supports DAP 
protocol version 2. 
Set this according to the controller.
NOTE: 
• 
Make sure the word count for the read/write domain matches that of the GDS file. If these 
do not match, the PROFINET module cannot function.
• 
A PROFINET interface can only be operated with 100 Mbps full-duplex. 
7.7 
EtherNet/IP
7.7.1 
Connector Diagram
This module has two status LEDs and two Ethernet connectors.
# Name
1 Network Status (NS) (LED)
2 Module Status (MS) (LED)
3 Ethernet Connector (Port 1)
4 Ethernet Connector (Port 2)
5,6 Link/Activity (LED)
7.7.2 
Network Status
Status Details
OFF IP address not set or module is not supplied with power
Green Online and connection established
Green blinking Online and waiting for connection
Red Duplicate of the IP address
Red blinking Connection timeout
NS MS
EtherNet/IP