JetMove D203-JC24X 12.10 Interface Cables
Jetter AG 123
On the HMI side
15-pin female SUB-D connector in metallized housing (quality grade 3).
Allowed conductor size: 0.25 ... 0.128 mm
2
Connecting Cable Specifications
Number of cores: 5
Core cross-sectional area: 0.14 mm
2
Cable length: xxxx cm
Max. cable length: 400 m
Cable Shielding
Complete shielding, no paired shielding
The shield must be connected to the connector housings on both ends of the
cable with the greatest possible surface area (shield twisted, clamped under the
strain relief clamps, and wrapped with copper foil).
HMI Cable KAY_0386-xxxx
Integrated
Controller
Shield LCD60
SER1, SER2 COM 2
Connect shield with the greatest
possible surface area!
Use metallized housing only!
Pin Signal Pin
1RDASDA14
2GNDGND5
3RDBSDB15
5SDBRDB13
7SDARDA12
short-circuited
[
11
10
Shield
Clamp
Shield