Fault Message Table for the JetMove D203
Error Number Type of Error Description Response to
Errors
Troubleshooting
F 00 Hardware Errors Internal hardware
defect
Immediate
pulse disable
Cut drive controller
from power lines
Return the amplifier
for repair
F 01 Internal voltage
supply error
One or more
power supply
voltages are
beyond their limits
Immediate
pulse disable
Cut drive controller
from power lines
Return the amplifier
for repair
F 03 Motor cable
breakage
The motor cable is
broken
Please be careful:
The motor cable is
tested when the
drive controller is
enabled for the
first time
Immediate
locking of
controller
Check the motor
cable connections
Acknowledge failure
F 04 Overvoltage in
the DC link
A DC link voltage
of> 480 V has
been detected
Immediate
locking of
controller
Check input voltage
supply
If the motor is used
as generator, reduce
the regenerating
power
Acknowledge failure