9 Diagnostics
82 Jetter AG
F 05 Current
overload
The output current
has been greater
than 2.5 x the
rated current or
ground fault during
operation
Immediate
locking of
controller
Check cable and
motor for a short
circuit and ground
fault
Check current
control parameters.
If necessary, correct
parameters
Acknowledge failure
F 06 Ballast resistor
overload
The ballast
resistor has been
overloaded
Immediate
locking of
controller
Let the amplifier cool
down
After cooling down,
acknowledge failure
Reduce regeneration
power
F 07 Amplifier
overtemperatur
e
The amplifier has
reached the
maximum
temperature
Immediate
locking of
controller
Let the amplifier cool
down
After cooling down,
acknowledge failure
Reduce power of
drive system
F 08 Motor
overtemperatur
e
The motor has
reached the
maximum
temperature
Immediate
locking of
controller
Let the motor cool
down
After cooling down,
acknowledge failure
Reduce the power of
the drive
F 09 Encoder failure Encoder breakage
or initialization
error
Immediate
locking of
controller
For extended
diagnostics
purposes use motion
setup
Check the encoder
line and all plug-in
connections
Acknowledge failure
F 10 Overspeed The actual shaft
speed has
exceeded a value
of 1.25 x
maximum speed
Immediate
locking of
controller
Check motor and
encoder connections
Check speed
controller
parameters. If
necessary, modify
parameters
Acknowledge failure
F 11 Current
overrange
A current
temporarily too
high has been
detected
Immediate
locking of
controller
Reduce K
p
of the
current controller by
10 to 20 %
Acknowledge failure