9 Diagnostics
82 Jetter AG
F 05 Current
overload
The output current
has been greater
than 2.5 x the
rated current or
ground fault during
operation
– Immediate
locking of
controller
– Check cable and
motor for a short
circuit and ground
fault
– Check current
control parameters.
If necessary, correct
parameters
– Acknowledge failure
F 06 Ballast resistor
overload
The ballast
resistor has been
overloaded
– Immediate
locking of
controller
– Let the amplifier cool
down
– After cooling down,
acknowledge failure
– Reduce regeneration
power
F 07 Amplifier
overtemperatur
e
The amplifier has
reached the
maximum
temperature
– Immediate
locking of
controller
– Let the amplifier cool
down
– After cooling down,
acknowledge failure
– Reduce power of
drive system
F 08 Motor
overtemperatur
e
The motor has
reached the
maximum
temperature
– Immediate
locking of
controller
– Let the motor cool
down
– After cooling down,
acknowledge failure
– Reduce the power of
the drive
F 09 Encoder failure Encoder breakage
or initialization
error
– Immediate
locking of
controller
– For extended
diagnostics
purposes use motion
setup
– Check the encoder
line and all plug-in
connections
– Acknowledge failure
F 10 Overspeed The actual shaft
speed has
exceeded a value
of 1.25 x
maximum speed
– Immediate
locking of
controller
– Check motor and
encoder connections
– Check speed
controller
parameters. If
necessary, modify
parameters
– Acknowledge failure
F 11 Current
overrange
A current
temporarily too
high has been
detected
– Immediate
locking of
controller
– Reduce K
p
of the
current controller by
10 to 20 %
– Acknowledge failure
Fault Message Table for the JetMove D203
Error Number Type of Error Description Response to
Errors
Troubleshooting

Table of Contents