SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
31217162 6-9
Battery Charger (ERT Machines) Hydraulic Oil
DESCRIPTION SPECIFICATION
Battery Charger Delta-Q
Electrical System Voltage (DC) 48V (1200 W)
Input
AC Input Voltage
Nominal AC Input Voltage
Input Frequency
Maximum AC Input Current
Ingress Protection
Operating Temperature
Storage Temperature
Output
Nominal DC Output Voltage
Maximum DC Output Voltage
Maximum DC Output Current
Derated
Protection
Output Reverse Polarity
Output Short Circuit
AC Overload
DC Overload
85 - 270V AC
100 - 240VAC
50 - 60Hz
14.5A
IP66
-40°F to 149°F (-40°C to 65°C)
-40°F to 185°F (-40°C to 85°C)
48V
72V
25.0A
> 104°F (40°F)
Electronic Protection-Auto Reset
Current Limited
Current Limited
Current Limited
HYDRAULIC SYSTEM OPERATING
TEMPERATURE RANGE
SAE VISCOSITY GRADE
0° to +23° F
(-18° to -5° C)
10W
0° to +210° F
(-18° to +100° C)
10W-20, 10W-30
+50° to +210° F
(+10° to +100° C)
20W-20