SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
31217162 6-21
Oil Change with Filter
Kubota Diesel (D1305-E4B)
Lube Point - Fill Cap/Spin-on Element
Lube - EO - Minimum API CF
Interval - Initial oil and filter change at first 50 hours of
operation, then every year or 200 hours of operation
Check oil level daily (1), maintain within marked level.
Change oil and filter (2) in accordance with engine man-
ual.
Kubota Dual Fuel (WG972-GL-E4)
Lube Point - Fill Cap/Spin-on Element
Lube - EO - Minimum API SL
Interval - Initial oil and filter change at first 50 hours of
operation, then every year or 200 hours of operation
Check oil level daily (1), maintain within marked level.
Change oil and filter (2) in accordance with engine man-
ual.
1
2
OAD02450
1
2
OAD02480