SECTION 3 - MACHINE CONTROLS, INDICATORS, AND MACHINE OPERATION
3-8 31217162
5. Engine Start Switch (RT Machines Only) - A momentary
contact push button type switch that supplies electrical
power to the starter solenoid when the emergency stop
switch is in the ON position and the start button is pressed.
6. Ground/Platform/OFF Key Selector Switch - A three posi-
tion, key-operated power selector switch supplies operating
power to the platform or ground controls, as selected. When
positioned to platform, the switch provides power to the
emergency stop switch at the platform controls. When posi-
tioned to ground, the switch provides power to the emer-
gency stop switch at the ground controls. With the power
selector switch in the center off position, power is shut off to
both platform and ground controls and the key can be
removed to disable the machine.
NOTE: With the power selector switch in the off position, the key can be
removed to disable the machine.
7. Genset Start Switch (If Equipped) - This button activates
the genset system to charge the batteries.
8. Genset Indicator (If Equipped) - This will illuminate when a
genset system fault is present.