2-17 
 
2.5.2.  GYRO I/F Circuit CMJ-304E 
DIP-SW/jumper setting 
 
(1)  TB100: Not to be used.    Leave the factory setting as is. 
(2)  TB105: Availability of setting if input voltage for the gyro is low 
1-2: Ordinary setting (factory setting) 
2-3: Setting when voltage for the gyro is low (CD56 is lighted when the voltage is 22 
VDC or less.  Even when the display system is turned off, the JMA-5200mk2 
operates receiving power from the display system side.  Thus, the switching of 
TB105 setting is not necessary. (This switching does not cause any problem.)    The 
JMA-5200MK2 needs the switching of TB105 setting.) 
 
(3)  TB106 and TB107: Not installed 
(4)  TB108 and TB109: Not installed 
 
(5)  TB401-TB403: Availability of setting if input voltage for the gyro is low 
1-2: Ordinary operation