6-31
6.3. Examples of Trouble
6.3.1. Internal Circuits
The radar display flickers on and off
Description
The radar is operating normally, but the radar display appears and disappears at intervals.
Location of cause
o
Procedure
Connection A connector may not be connected correctly. Check the connection of
the RGB connector (J7) and LCD power connector (J6).
Input voltage The input voltage may be too low. Check the voltage.
The power cannot be turned on.
Description
Pressing the power switch does not start the equipment.
Location of cause
o
Procedure
Circuit breaker Check that the circuit breaker is turned on.
Input voltage The protection circuit may be activated because the input voltage is too
high. (Preset protective voltage +42 VDC)
Check the voltage.
The cursor cannot be operated with the trackball.
Description
The cursor cannot be moved by operating the trackball.
Location of cause
o
Procedure
Setting Check that the equipment is not in a mode for operation with the EBL or
VRM control.
To return to the ordinary operation mode, hold down EBL.
Trackball If operation with the EBL or VRM control is also impossible, replace the
trackball.

Table of Contents

Other manuals for JRC JMA-5212-4/6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-5212-4/6 and is the answer not in the manual?

JRC JMA-5212-4/6 Specifications

General IconGeneral
BrandJRC
ModelJMA-5212-4/6
CategoryMarine Radar
LanguageEnglish

Related product manuals