4-36
4.9.4.1. Setting RS-485ID
To identify a display unit on the RS-485 network, set an ID for each display unit.
To use RS-485, an ID must be set.
Avoid duplication of ID among the display units. Otherwise, data and dimmer linkage are not possible.
Available IDs are from 1 to 10.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Select “RS-485ID” by using
.
3. Enter an ID number by using
and press .
4.9.4.2. Linking dimmer control
Dimmer control linkage is available for the display units that are connected by the RS-485 network.
The following conditions are necessary for the linkage.
1) The display units must be connected by RS-485.
2) The same dimmer control is used.
3) The display units are in the same dimmer group.
Set the details by referencing the following sections.
1) Set RS-485ID by referencing “4.9.4 1 Setting RS-485ID”.
2) Select the same dimmer unit by referencing “4.9.3 Selecting a dimmer unit”.
3) Set the display units in the same dimmer group by referencing “4.9.4.3 Setting a dimmer group”.
To disable linkage of dimmer control even though the display unit is connected by the RS-485
network, change the dimmer group.
4.9.4.3. Setting a dimmer group
Set a group within which dimmer control for this display unit is linked.
Available dimmer group numbers are from 1 to 10.
Set a dimmer group when the display units for which dimmer control is to be linked need to be grouped
due to the different equipment environment even though the units are connected by RS-485.
Select the same dimmer unit within the same group. Otherwise, dimmer control cannot be linked within
the group.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Select “DIMMER GROUP” by using
.
3. Enter a group number by using
and press .
Since dimmer data is transmitted between display units, some time lag may occur at dimmer
switching.
Caution