Error
code
Description of error Cause Item to be checked
E750 Sewing machine
stops
In the case the optional-input safety
switch is pressed.
E811 Over-voltage
In the case a voltage that is equal to or
more than the guaranteed voltage is
input.
In the case a voltage of 200 V is applied
though the voltage is set to 100 V.
In the case a voltage of 220 V is input
to the box of "JA: 120 V".
In the case a voltage of 400 V is applied
to the box of "CE: 230 V".
Check whether the supply voltage of
"rated supply voltage ±10 % or more"
is applied.
Check whether the 100 V/200 V
changeover connector is set correctly.
In the above-described cases, the
power PCB has broken.
E813 Low voltage
E815 Regenerative
resistor is not
connected
In the case the regenerative resistor is
not connected.
Check whether the regenerative
resister is connected to the
regenerative resistor connector
(CN11).
E900 Main shaft motor
IPM overcurrent
protection
Maloperation of the main shaft motor.
E901 Main shaft motor
IPM overload
E903 85-V power supply
fault
In the case the 85-V voltage is not
properly output.
Check whether the stepping motor is
faulty.
Check the F2 fuse.
E904 24-V power supply
fault
In the case the 24-V voltage is not
properly output.
E910 The presser motor
origin retrieval error
In the case the presser motor has failed
to return to its origin.
Check whether the presser setting is
correct (memory switch No. 23).
Check whether the presser motor
origin has been correctly adjusted.
E912 Main shaft motor
speed detection
error
E915 Failure of
communication with
operation panel
In the case communication with the
operation panel cannot be carried out.
E918 Main shaft
temperature error
In the case the temperature of the CTL
PCB is excessively high.
E922 Main shaft control
failure
In the case the main shaft motor is out
of control.
E924 Motor driver fault
In the case the motor driver has broken.
E946 Machine-head
EEPROM write error
In the case the machine head PCB is
not correctly connected.
Check whether CN32 has loosened
or come off.
E955 Electric current
sensor error
Main motor shaft failure.
Electric current sensor failure.
Check whether the main shaft motor
has short-circuited.
E961 Pitch motor deviation
error
In the case the pitch motor fails to
operate because of an excessive load.
Check whether the pitch motor runs
smoothly.
E962 Presser motor
deviation error
In the case the presser fails to operate
because of an excessive load.
Check whether the presser motor
runs smoothly.
E963 IPM temperature
error
In the case the temperature of the CTL
PCB is excessively high.
– 69 –

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI DDL-9000C-F and is the answer not in the manual?

JUKI DDL-9000C-F Specifications

General IconGeneral
BrandJUKI
ModelDDL-9000C-F
CategorySewing Machine
LanguageEnglish

Related product manuals