No.
Item
Setting range Unit
Initial value
SMS SSH FMS FSH
SMS CE
SSH CS FMS CE FSH CE
K103
Needle cooler output-off delay time
Delay time from a stop until an output-off, using the
needle cooler output function
100 to 2000 ms 500 500 500 500 500 500 500 500
K105
BT Angle that ends prohibition of output operation
The reverse-feed stitching output is prohibited below the
set angle.
0 to 359
Degree
112 112 112 112 112 112 112 112
K106
BT Angle that starts prohibition of output operation
The reverse-feed stitching output is prohibited over the
set angle.
0 to 359
Degree
262 262 262 262 262 262 262 262
K111
Sewing speed according to a fan motion
0: A fan motor always rotates. /100 and up: A fan motor
rotates when the current sewing speed exceeds the set
sewing speed.
0 to 4000 sti/min 0 0 0 0 0 0 0 0
K118
Cancellation of a grease-up error
If it is enabled at the time of power activation, clear a
counter of the number of stitches for a grease-up error
and its settings.
0: Disabled/1: Enabled
0 to 1
-
0 0 0 0 0 0 0 0
K125
Speed settings for one-touch type reverse feed
0: Disabled/1: Enabled
150 to 5000 sti/min 4000 4000 4000 4000 4000 4000 4000 4000
K126
Time for detecting if the sewing machine is being
locked
500 to 2000
ms
1000 1000 1000 1000 1000 1000 1000 1000
K130
AT correction value
−30 to 50
-
20 20 20 20 20 20 20 20