No.
Item
Setting range Unit
Initial value
SMS SSH FMS FSH
SMS CE
SSH CS FMS CE FSH CE
K184
The number of needles ignoring the sewing counter
switch
When the number of sewing needles used at the time
of the thread trimming is less than that of needles set in
the sewing machine, the sewing counter switch is not
accepted. (Both the sewing counter and the ISS data
recording are a target.)
0: Disabled
0 to 99 Stitch 0 0 0 0 0 0 0 0
K291
Angle at which operation of the AK is turned ON for
the thread presser
Angle at which operation of the AK starts when the
thread presser operates
50 to 359
Degree
200 200 200 200 200 200 200 200
K321
Change in the vertical phase of the feed locus
−30 to 30
Degree
0 0 0 0 0 0 0 0
K330
Pitch correction in the forward direction
50 to 150 % 100 100 100 100 100 100 100 100
K331
Pitch correction in the reverse direction
50 to 150 % 100 100 100 100 100 100 100 100
K420
Network connecting function
0: Disabled network connecting function/1: Enabled
network connecting function
0 to 1
-
0 0 0 0 0 0 0 0
K430
ISS function
Set whether to use the ISS data measurement function.
0: Not used /1: Use
0 to 1
-
0 0 0 0 0 0 0 0
K437
ISS backup data initialization
With the settings of the selection 1, initialize the ISS
backup data. (After initialization, the selection 1 returns
to the selection 0 automatically.)
0 to 1
-
0 0 0 0 0 0 0 0
– 113 –