Initially Configuring the ACX1000 or ACX1100 Router on page 103
•
Configuring External Clock Synchronization for ACX Series Routers
6. Issue the show chassis synchronization command to check the status of the port.
user@host> show chassis synchronization
Clock Synchronization Status :
Clock module on CB 0
Current state : master
Current clock state : internal
Selected for : 13 days, 23 hours, 15 minutes, 17 seconds
Selected since : 2012-10-29 18:28:35 EDT
Deviation (in ppm) : +0.00
Last deviation (in ppm): +0.00
Clock Synchronization Status :
Clock module on CB 1
Current state : backup
Current clock state : locked to master CB
Selected for : 13 days, 23 hours, 14 minutes, 23 seconds
Selected since : 2012-10-29 18:29:29 EDT
See Also • External Clocking Ports Specifications on the ACX1000 and ACX1100 Router on page 75