Table 21: AC Power Cord Specifications (continued)
Juniper Model NumberPlug StandardsElectrical SpecificationsCountry/Region
CBL-EX-PWR-C13-SZSEV 6534-2 Type 12G250 VAC, 10 A, 50 HzSwitzerland
CBL-EX-PWR-C13-TWNEMA 5-15P Type N5-15P125 VAC, 11 A and 15 A,
50 Hz
Taiwan
CBL-EX-PWR-C13-UKBS 1363/A Type BS89/13250 VAC, 10 A, 50 HzUnited Kingdom
Figure 37 on page 57 illustrates the plug on the power cord for some of the countries or regions listed in
Table 21 on page 56.
Figure 37: AC Plug Types
DC Power Supply for ACX5400 Routers
The two power supply modules (PSMs) in ACX5400 routers are hot-removable and hot-insertable
field-replaceable units (FRUs). The PSMs are installed in the router at the factory. The DC power supply
in ACX5448 is 650 W and ACX5448-D and ACX5448-M is 850 W with dual feeds for power resiliency.
You can install replacement PSMs without powering off the router or disrupting the router function.
NOTE: Both the AFI and AFO PSMs look identical. Be sure to use the correct PSM for your
chassis product model (see Table 22 on page 58).
CAUTION: Do not mix PSMs with different airflow. The system raises an alarm when
a PSM with a different airflow is inserted into the chassis.