admin@host# set chassis config-button no-rescue
You can still press and hold the button for 15 seconds or more to reset the gateway to
the factory-default configuration.
•
To disable the button and prevent the device from resetting to either configuration:
admin@host# set chassis config-button no-clear no-rescue
The no-clear option prevents the RESET CONFIG button from deleting all configurations
on the services gateway. The no-rescue option prevents the RESET CONFIG button from
loading the rescue configuration.
To return the function of the RESET CONFIG button to its default behavior, remove the
config-button statement from the device configuration.