D3DA3xx/x Mountingandinstallationinstructions
ProjectengineeringmanualV1.00
27
©KEBA
● Encoderconnector
● Connectorsformotor
● Connectorbrakeresistor
● Supplyconnectors
● Equipotentialboundinglines
RTEthernet(RJ45)connectors
Ifan(RT)Ethernetcableisledoutsideofthecabinet,theisolationoftheca
blemustbeopenedca.2030mmaftertheRJ45plugandthecableshield
mustbecontactedonthedesignatedstraps(lowerendofthefrontplate)
again.Thefollowing(RT)Ethernetconnectorscanbeaffected:
Illustration55:Cableshield
1 ...Cableshieldwithshieldclamp 2 ...Controlmodule
3 ...Supplymodule 4 ...Cabinet
Encoderconnectors
Allencodercablesmustbeshielded.AllavailablecablesfromKEBAare
listedintheappendix.Forconnectingthirdpartymotors,equivalentcables
mustbeused.
Connectorsforthemotor
Allmotorcablesmustbeshielded.AllavailablecablesfromKEBAarelisted
intheappendix.Forconnectingthirdpartymotors,equivalentcablesmust
beused.