D3DA3xx/x TechnicalData
ProjectengineeringmanualV1.00
95
©KEBA
● Repetationratemustbe≥30ms.
Caution
Durationofthetestpulsesbetween0.75msand2msresultsanunwanted
shutdownafterunpredictabletime.Thisinformationappliesirrespectiveof
wheterthemonitoringofexternaltestpulsesisswitchedofforon.
12.6 Ambientconditions
AccordingtoEN618001andtheincludedandreferencedenvironmentclas
sifyingofstandardsIEC604213.
Operation:
accordingtoEN618002,IEC6072133
class3K3
● Temperature:
5°Cto+40°C(4,8,16kHz)to50°Cwith
performancereduction(5%/°C)
● Relativehumidityofair: 5to85%
1)
Storage:
accordingtoEN618002,IEC6072131
class1K3and1K4
● Temperature: 25°Cto+55°C
● Relativehumidityofair: 5to95%
2)
Transit:
accordingtoEN618002,IEC6072132
class2K3
● Temperature: 25°Cto+70°C
● Relativehumidityofair: 95%withmax.+40°C
3)
Vibrationresistance: accordingtoEN618002
Shockresistance: accordingtoEN618002
Protectionclass:
IP20(allconnectionterminalsIP00),when
usingsafetyfunctions,installationinIP54
cabinetnecessary.
Mountingheight:
to1000moverNN,abovewithperformance
reduction(1%per100m,max.2000mo.
NN)
Contaminationlevel: 2
1)
Theabsolutehumidityislimitedtomax.25g/m³.Thatmeansthatthemax
imumvaluesfortemperatureandrelativehumiditystipulatedinthetable
mustnotoccursimultaneously.
2)
Theabsolutehumidityislimitedtomax.29g/m³.Sothemaximumvalues
fortemperatureandrelativehumiditystipulatedinthetablemustnotoccur
simultaneously.