D3DA3xx/xConnectionsandwiring
ProjectengineeringmanualV1.00
60
©KEBA
Information
Fordetailedinformationonparameterizationofthecontrolinputsreferto
DriveManagerdevicehelp(integratedinDriveManager).
6.7.2 Safedigitalinputs(terminalX26A)
Illustration637:TerminalX26A
Selectionlist,functionofthecontrolinputs
X26A Typ Function
SDI00 Safedigitalinput STO1CH1
SDI01 Safedigitalinput STO1CH2
SDI02 Safedigitalinput STO2CH1
SDI03 Safedigitalinput STO2CH2
GND Referenceground GND
GND Referenceground GND
Information
Furtherinformationaboutsafetyfunctionssee8Safetyfunctions.
6.7.3 Specificationoftheterminals
ThecontrolterminalX25Aisrealisedusinga2layer2x6poleplugintermi
nalwith3.5mmspacingfromPhoenixContact.
● Type:MCDN1,5/6G13,5
ThesafetyterminalX26Aisrealisedusinga2layer2x3poleplugintermi
nalwith3.5mmspacingfromPhönixContact.
● Type:MCDN1,5/3G13,5
Connectorsets
Connectorsetssuitable
for
OrdernumberKEBA.
D3XT230/Aforcontrolwires
Singleaxismodule,double
axismodule,tripleaxismod
ule
94801