D3DA3xx/xMountingandinstallationinstructions
ProjectengineeringmanualV1.00
24
©KEBA
5 Mountingandinstallationinstructions
Duringtheinstallationitisimperativetoavoid
Drillchippings,screwsorforeignbodiesdroppingintothedevice
Moistureenteringthedevice
WARNING!
Dangerousvoltagemaybeappliedtothedevice,evenifthedevicedoes
notemitanyvisualoraudiblesignals/indications!
Caution
Installationmustonlybecarriedoutbyqualifiedelectricianswhohaveun
dergoneinstructioninthenecessaryaccidentpreventionmeasures.
Caution
Electricdrivesaredangerous:
Electricalvoltages230/400/480VACor325/565/678VDC
Dangerouslyhighvoltages≥50V(capacitorcharge)maystillbepresent
3minutesafterthepoweriscut.Socheckthatelectricalpowerisnot
present!
Payattentiontowarningsignonthedevice(seefrontofdevice).
Information
Forinstallingthesupplymodulewithinasystem,alsonotetheprojectman
ualsofthecontrolmoduleandtheaxismodule.
Controlcabinet
Thedevicesaresolelyintendedforinstallationinastationarycabinet.
ThecabinetmustasaminimumprovideIP44protection.Accordingto
ENISO138492thecabinetmusthavedegreeofprotectionIP54or
higheronusingthesafetyfunctionsintheaxismoduleoraD3DU3x5/
x.
Environment
Theaxismodulesmustnotbeinstalledinareaswheretheyareexposed
tocontinuousvibration.(See12.6Ambientconditions).
Pollution
Max.pollutionseverity2toEN606641.(See12.6Ambientconditions).