D3DA3xx/x Connectionsandwiring
ProjectengineeringmanualV1.00
61
©KEBA
6.8 Motorconnection
1) Specifythecablecrosssectiondependentonthemaximumcurrentand
ambienttemperature.
Thebestmethodisusethepreassembledmotorcable,formorede
tailedinformationsee15.2Connectiontechnology.
2) ConnecttheshieldedmotorcabletoterminalsX31/A/X31/B/X31/C,U,
V,Wconnectthemotortoearthatearthsymbol.
Mountshieldatbothendstoreduceinterferenceemission.Fastenshield
connectionplateforthemotorconnectionMotor1usingbothscrews.
Whenusingtheappropriatemotorcableasdescribedin15.2Connection
technology,theshieldcontactsalreadyexistonbothsides.
3) Wirethetemperaturesensor(iffitted)toX31/A/X31/B/X31/Cusing
separateshieldedcablesandactivatethetemperatureevaluationusing
DriveManager.
Themotorcablesdescribedin15.2Connectiontechnologyhavea
shieldedwirepairfortemperatureevaluationintegratedandtheshield
hascontactwiththeconnectorsonbothsides.
4) Iffitted,connectthemotorbraketoX31/A/X31/B/X31/C1,2.
Themotorcablesdescribedin15.2Connectiontechnologyhavea
shieldedwirepairformotorbrakeintegratedandtheshieldhascontact
withtheconnectorsonbothsides.
Information
Onlyusemotorsthatpermitconnectionofthemotortemperaturesensor
exclusivelytoterminalsX31/A/X31/B/X31/C1,2ontheaxismodule.
Thisissueistobeexpresslystatedonorderingthemotor.
Motorcables:
Allmotorcablesmustbeshielded.ThecablesavailablefromKEBAare
listedontheappendix,see15.2Connectiontechnology.Equivalentshielded
cablesmustbeusedfortheconnectionofmotorsfromothermanufacturers.
Information
Intheeventofashortcircuitorearthfaultinthemotorcable,thepower
stageisdisabledandanerrormessageisissued.