background may cause interruption in the data flow to the laser system which may cause errors in the KCAM
software. All screen savers must be disabled as well.
Air Supply (Minimum Requirements)
65 90 PSI of clean, dry air (Volume of 3 CFM)
Air must be filtered before it reaches the laser system for both oil and water.
Recommend 5 micron pre-filter and 0.1 micron filter.
Oxygen and nitrogen may be used for metal cutting (regulated for 0-150 PSI output).
Must use separate air lines for compressor air and oxygen/nitrogen to back of laser system.
Power Requirements
Due to electrical panel variations please contact your salesman for the exact electrical requirement of your
system.
Additional Components
Additional components the end user may need to purchase are: distilled water for chilling unit, power cord for
connection to the electrical panel, air compressor with hose connection, oxygen and/or nitrogen assist gases,
venting hardware for exhaust system, additional hose for the blowers and paper for sealing the table top
vacuum.