Chapter 3: System operation
146 P/N 3102351-EN • REV 005 • ISS 28DEC18
ID
Event description
130
Zone 19 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 19)
131
Zone 20 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 20)
132
Zone 21 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 21)
133
Zone 22 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 22)
134
Zone 23 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 23)
135
Zone 24 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 24)
136
Zone 25 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 25)
137
Zone 26 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 26)
ID
Event description
138
Zone 27 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 27)
139
Zone 28 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 28)
140
Zone 29 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 29)
141
Zone 30 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 30)
142
Zone 31 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected in zone 31)
143
Zone 32 (active, trouble, disable, prealarm,
alarm verify, maintenance alert, or test was
detected on zone 32)
144
to
342
CorrGrp nnn: Correlation group nnn is
disabled through User key which is
configured as Disable (Group/Both)
Note: nnn represents the correlation group
number (001 to 199).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kidde VS Series and is the answer not in the manual?

Kidde VS Series Specifications

General IconGeneral
Power Source120V AC
Battery Backup9V battery
Sensor TypePhotoelectric
Alarm Sound Level85 dB at 10 feet
Hush FeatureYes
Test ButtonYes
LED IndicatorYes
Mounting TypeWall or ceiling
ComplianceUL 217

Related product manuals