Real speed (rpm)
Internal sampling time: 200 mS
Real speed (0.01 rpm)
Internal sampling time: 200 mS
Speed data (inc/1 mS)
Internal sampling time: 1 mS
Internal effective current instruction
Position data captured by encoder index
signals
Parameter List: Group F002 (To Set Control Loop Parameters)
1: Stores all control parameters except motor
parameters
10: Initializes all control parameters except
motor parameters
Sets the response speed of velocity loop
Time used to adjust speed control to
compensate minor errors
Notch/filtering frequency setting for a velocity
loop, used to set the frequency of the internal
notch filter, so as to eliminate the mechanical
resonance produced when the motor drives the
machine. The formula is F=Notch_N*10+100.
For example, if the mechanical resonance
frequency is F = 500 Hz, the parameter should
be set to 40.
Enable or disable the notch filter
0: Disable the trap filter
1: Enable the trap filter
You can reduce the noise during motor
operation by reducing the feedback bandwidth
of velocity loop. When the set bandwidth
becomes less, the motor responds slower.
The formula is F=Speed_Fb_N*20+100.
For example, to set the filter bandwidth to "F =
500 Hz‖, you need to set the parameter to 20.
0: Speed response after traveling through a