11.2. Other possible errors
RemedyCauseFault
The fan is not working. No mains power. Check the residual-current circuit breaker and
the fuse in the power supply.
Fuse SI4 has blown. Replace fuse SI4 (1.6 AT) or contact KLAFS
service engineers.
D customerservice@klafs.de
The fan is defective. Replace the fan.
1. Disconnect the controller from the
mains.
2. Replace with a fan of the same
wattage.
The main switch is not switched
on.
Switch on the main switch.
No power at output AG1. Fuse AG1 SI1 has blown. Replace fuse AG1 SI1 (1.6 AT) or contact
KLAFS service engineers.
D customerservice@klafs.de
No power at output AG2. Fuse AG2 SI2 has blown. Replace fuse AG2 SI2 (1.6 AT) or contact
KLAFS service engineers.
D customerservice@klafs.de
The controller is in standby mode. Start a bathing mode.
The LED on the
evaporator lights up, the
Cloud symbol flashes in
the controller display
(SANARIUM S).
There is no water. Open the angle valve on the evaporator.
D See page 51.
There is no steam
escaping
(SANARIUM S).
The angle valve on the
evaporator is closed.
Open the angle valve on the evaporator.
D See page 51.
The evaporator is not switched
on.
Switch on the evaporator.
D See page 51.
Evaporator fault. D See page 92.
The fuse in the cable has tripped.
The inlet pump is faulty. D Contact KLAFS service engineers.
D customerservice@klafs.de