11.2. Other possible errors
RemedyCauseFault
Yellow or red LED on the
evaporator lights up
(SANARIUM S).
The evaporator must be serviced. Service the evaporator.
D See page 92.
The steam cylinder is worn.
The inlet pump is faulty. D Contact KLAFS service engineers.
D customerservice@klafs.de
The drain pump is faulty.
D Only with
evaporator S
with
Birmingham
scent dispenser:
No scent discharged.
(SANARIUM S).
The scent container is empty. Replace the scent container.
D See page 93.
The scent pump does not work or
is defective.
D Contact KLAFS service engineers.
D customerservice@klafs.de
The feed hose in the pump is
defective.
D See servicing instructions
50701466/50701467.
The scent line is clogged or
defective.
Check the scent line from the pump to the
evaporator tube.
Replace the defective scent line.
The scent inlet at the T-piece to the
evaporator tube is clogged.
Check the scent line to the evaporator tube.
Clean the scent inlet at the T-piece to the
evaporator tube.
D See page 93.
The controller cannot be
started or operated.
The controller is controlled by
TOUCHCONTROL.
The operating panel is locked.
Turn off TOUCHCONTROL.
D After approx. 5 minutes,
TOUCHCONTROL activates the
controller.
Disconnect the data lead between the
TOUCHCONTROL and the controller.
The controller cannot be
operated.
The touchscreen lock symbol
appears on the touchscreen.
The touchscreen lock is switched
on.
Switch the touchscreen lock off.
D See page 72.