MV-6 - Protocol 3000 Commands
Command Type - Multiviewer
#OVRLTXT␠stage,stage_id,type,size,x,y,string␍
#OVRLTXT?␠stage,stage_id ␍
~ nn@OVRLTXT␠stage,stage_id,type,size,x,y,string␍␊
stage - input/output (see Section 12.4 Stage)
stage_id - number of chosen stage (1.. max number of inputs/outputs)
type - font type (only 0 supported currently, TBD)
size - font size (see Section 12.8 Font Size) for values
x - horizontal alignment (0 - Left, 1- Centered, 2- Right)
y - vertical alignment (0 - Top, 1- Centered, 2- Bottom)
string - tile text (up to 10 characters)
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if OVRLTXT was set by any other external control device
(button press, device menu and similar)
Command Type - Multiviewer
~ nn@ W-ACTIVE␠ win_num␍␊
win_num - window number setting active
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if W-ACTIVE was set by any other external control
device (button press, device menu and similar)