58
MV-6 - Protocol 3000 Commands
Command - OVRLTXT
Command Type - Multiviewer
Command Name
Permission
Transparency
Set:
OVRLTXT
End User
Public
Get
OVRLTXT?
End User
Public
Description
Syntax
Set:
Set overlay text
#OVRLTXTstage,stage_id,type,size,x,y,string
Get:
Get overlay text
#OVRLTXT?stage,stage_id
Response
~ nn@OVRLTXTstage,stage_id,type,size,x,y,string␍␊
Parameters
stage - input/output (see Section 12.4 Stage)
stage_id - number of chosen stage (1.. max number of inputs/outputs)
type - font type (only 0 supported currently, TBD)
size - font size (see Section 12.8 Font Size) for values
x - horizontal alignment (0 - Left, 1- Centered, 2- Right)
y - vertical alignment (0 - Top, 1- Centered, 2- Bottom)
string - tile text (up to 10 characters)
Response Triggers
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if OVRLTXT was set by any other external control device
(button press, device menu and similar)
Notes
Command - W-ACTIVE
Command Type - Multiviewer
Command Name
Permission
Transparency
Set:
W-ACTIVE
End User
Public
Get
W-ACTIVE?
End User
Public
Description
Syntax
Set:
Set active window
#W-ACTIVE win_num
Get:
Get active window
#W-ACTIVE?
Response
~ nn@ W-ACTIVE win_num␍␊
Parameters
win_num - window number setting active
Response Triggers
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if W-ACTIVE was set by any other external control
device (button press, device menu and similar)
Notes