Commissioning
26
Pos: 15.14 /BA/Ers tinbetriebna hme/EasyCut/ Anbau Weiste-Drei eck @ 3\m od_12046408 90345_78.doc @ 71160
5.4 Installation of Weiste triangle
AFL 245-0-007
1
Fig. 6:
Pos: 15.15 /BA/Sic herheit/Gefa hrenhinweise/Mä hwerke/Warn ung Anbau des Kuppeldreiec ks (Weiste Dreie ck) @ 3\ mod_12046383784 07_78.doc @ 7 1102
Warning
Installation of the triangle linkage (Weiste triangle)
Effect: Danger to life or serious injuries. Considerable damage to the machine
Observe manufacturer's operating instructions for the triangle linkage!
Pos: 15.16 /BA/Ers tinbetriebna hme/EasyCut/ Anbau Weiste-Drei eck Text @ 3 \mod_1204 638631735_78. doc @ 71179
For the installation of the front-mounted disc mower, a Weiste triangle (1) is attached to the front
hydraulics. Adjust the top suspension arm in such a way that the triangle is inclined slightly
forward.
Pos: 15.17 /BA/Ers tinbetriebna hme/EasyCut/ Vorbereitung a m Frontscheibe nmäher EC 28/ 32 28P/32P 28M @ 10\mod_ 12216598101 03_78.doc @ 136162
5.5 Preparation on the front-mounted disc mower
EC-1-005
Fig. 7:
• Push the PTO shaft (3) with full protection (4) onto the PTO shaft end of the machine.
• The safety mechanism must engage
• Secure the PTO shaft guard (2) against turning with pipe clamp (2).
Pos: 15.18 /BA/-- ---Seitenum bruch------ @ 0\m od_119617531 1226_0.doc @ 4165