130 / 151 Issued: 16.06.2010 Version: MA KL 1500-3 T S 141215 V1 en
KL 1500-3; KL 1500-3 T; KL 1500-3 S
15.1.2.6 Measures after unintended release
15.1.2.7 Handling and storage
15.1.2.8 Exposure limits and personal protective equipment
Special fire-fighting
measures:
-
Protection of fire-fighters:
Fire-fighters must wear self-contained positive pressure breath-
ing apparatus (SCBA) and full protective gear.
Personal safety
precautions:
In case of spillage, isolate the hazard area. Avoid contact with
the hazardous substance and avoid inhaling vapors. Ensure
adequate ventilation. Where there is insufficient ventilation,
wear suitable respiratory equipment. Use suitable protective
equipment.
Environmental protection
measures:
Prevent the product from entering the drainage system, surface
waters and soil. Notify the competent authorities, if required.
Large spills:
Stop the leak if you can do so without risk. Remove container
from spill area. Flush spilled material into a wastewater treat-
ment plant. Contain spilled material using a non-combustible
absorbent (e.g. sand, soil, vermiculite, diatomaceous earth) and
collect in the containers provided. Disposal should be entrusted
to a recognized waste disposal company. Contaminated
absorbents can be just as dangerous.
Small spills:
Stop the leak if you can do so without risk. Remove container
from spill area. Dilute with water and mop up, or add absorbent
material and place the substance in a suitable container for dis-
posal. Disposal should be entrusted to a recognized waste dis-
posal company.
Handling:
Prevent contact with skin or clothing. Spilled and leaked product
must be prevented from coming into contact with soil and sur-
face waters. Wash thoroughly after handling.
Storage:
Keep containers tightly sealed. Keep containers in a cool, well-
ventilated area.
Unsuitable:
Avoid prolonged exposure to increased temperatures.
VCI storage class:
11
Threshold limit values
(TLV):
No occupational exposure threshold limit values have been
assigned for this product.
Protective measures
Limitation and monitoring of
exposure in the workplace:
Provide exhaust ventilation or other engineering controls.
Hygiene measures:
Wash hands, forearms and face thoroughly after handling
chemical products.
Respiratory protection:
Sufficient ventilation is recommended in industry. If ventilation is
insufficient, respiratory protection is useful.
Hand protection:
Wear chemical-resistant gloves (recommended: nitrile gloves) if
prolonged or repeated contact is likely.