108 / 151 Issued: 16.06.2010 Version: MA KL 1500-3 T S 141215 V1 en
KL 1500-3; KL 1500-3 T; KL 1500-3 S
If more than three ranges are monitored, the electric cabling must be wired us-
ing an additional connector.
14.1.1 Technical data
Mechanical data
* The overall length of a cam (consisting of one or more sections) corresponds
to the size of the respective monitoring range. The monitoring range can be
reduced or increased by shortening the cam or assembling several individual
sections.
Electrical data
14.1.2 Installing the working range monitoring
Procedure 1. Determine the installation position of the brackets (>>> Fig. 14-2) on the
beam.
2. Mount the brackets, align them and tack-weld them in place. Observe the
specified distance from the track. See (>>> Fig. 14-3) for installation di-
mensions.
3. Mount the cams, align them and tack-weld them in place. Observe the cor-
rect installation dimensions.
Caution!
The user is responsible for this wiring in case of retrofits.
Max. monitoring range
Full range of motion of A 7
Number of monitoring ranges
max. 6
Length of one individual cam*
max. 2500 mm
Contact elements
1 make contact, 1 break contact
Switching voltage
250 V AC
Switching current
10 A
Position switch type
3SE5112-0CH01
Protection classification
(according to IEC 529)
IP 67
Warning!
The relevant safety regulations are to be observed when carrying out weld-
ing. This applies especially to sparks and hot components.
The installation situation of the brackets and the location of the cams is
shown in the drawing supplied with the retrofit kit. It is much easier to align
the brackets and cams if a suitable installation aid is used.