KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 185 -
Inspection UP in the pit, „1“ = UP
Inspection DOWN in the pit, „1“ = DOWN
Inspection fast-switch in the pit, „1“ = FAST
E532 Inspection Pit: Reset
Reset for the Shaft-Door Bottom (EN81-20/50) „1“ = Reset
If the level is „1“, then the automatic Car-Call is OFF in menu B21
Counter level Energy-Counter is increasing for 1 KWh
Counter level Recover Energy-Counter is increasing for 1 KWh
If the level is „1“, then there is Message Overvoltage of the Monitoring
If the level is „0“, then error message of the Cabinet-fan
If the level is „0“, then error message of the Carlight ( One Light is
Out-of-order)
If the level is „0“, then error
If the level is „0“, then error
If the level is „0“, then error
If the level is „0“, then error
E543 Electric Socket Monitoring
If the level is „0“, then error
E444 Fan Monitoring Active
If the level is „1“,then Monitoring-function E537 is active
If the level is „0“, then error
E546 Car fan Monitoring Active
If the level is „1“, then Monitoring-function E545 is active
E547-Controler & Light OFF-3
Like Standby travel E16, but with error message
E548- Controler & Light OFF-4
Like Standby travel E362, but with error message
If the level is „1“, then ok
If the level is „1“, then ok
FireFighter: Erase the Carcalls (FW-Düsseldorf)