KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 248 -
red button on the HPG-60 or the quick but-
ton on the inspection control.
The elevator car is driven flush with inspec-
tion in the lowest stop and with the help of
the HPG-60, this stop is synchronized. As a
result, all floors are learned!
3.9A Floors learn with the method„ Manually start
Use the maintenance key downwards to se-
lect the setting "manually approach".
Use the yellow buttons to set the value
"Yes".
.. and press the ENTER key!
Display now indicates that the lowest
floor should be installed
OR
Therefore, the lowest floor will start manu-
ally
(INSPECTION OR RETURN CONTROL)
Now press the red "UP" button in the
HPG or press the QUICK button on the in-
spection bulb
Sequence:! The piezo will sound in the
cabin for 1 second and the text "Floor
stored" will be displayed as confirmation in
the 3rd line
Learn next floor by:
Pressing the UP-button on the inspection
bulb or if the HPG-60 is being used, press
the ENTER button. The 3
rd
line is activated:
Display 3
rd
line: “Input: UP button”.
1.) The floor-02 with start inspection (or re-
turn).
2.) Press the QUICK button on the inspec-
tion bulb, or press the UP button if the
HPG-60 is being used.
Note: If the penultimate floor is reached, then the top floor is automatically occupied (limit
switch TOP:-100mm)
Result: The piezo sounds in the cabin for 1 second and in the 3
rd
line the text “Floor
saved” is displayed as confirmation
Now switch the elevator to normal opera-
tion
Go to STEP 3.10