KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 247 -
2.) A YES is entered in the menu.
The LIMAX CP33 limit switch TOP position is
saved!
3.8 Learning the lower limit switch
1.) Approach limit switch position DOWN with
the return control. Stop the elevator car when
reaching position.
2.) A YES is entered in the menu.
The LIMAX CP33 limit switch DOWN position
is stored!
From now on, the safety circuit is now closed if the lift-cab is inside
the limit switch.
3.9 STEP-2: D613-Learn floors and adjust Precision
There are two ways to learn the floors, in the B43 menu Learning floors
All, except for the top stop are approached
with inspection. The car is leveled and the
position is learned and accepted with the
All flush values in mm were entered into the
manhole table of the control system on the
basis of the manhole height.