PARAMETER PARKINGZONE
In the menu B25-Group controler it is possible to have above 5 different parking zones. For each park-
ing zone you can put in the priority. The parking zone with the highest priority ( lowest number) has the
quickest drive in.
- Parkingzone-1: OFF / ON, Priority-1/ ON, Priority-2 ….ON, Priority-5/ ON
- Parkingzone-2: OFF / ON, Priority-1/ ON, Priority-2 ….ON, Priority-5/ ON
- Parkingzone-3: OFF / ON, Priority-1/ ON, Priority-2 ….ON, Priority-5/ ON
- Parkingzone-4: OFF / ON, Priority-1/ ON, Priority-2 ….ON, Priority-5/ ON
- Parkingzone-5: OFF / ON, Priority-1/ ON, Priority-2 ….ON, Priority-5/ ON
For each active parking zone you can put in the day and the time, if the parking zone is active or tilt for
a certain time. For the controlling, you can use certains timers (Timer-01 to 10). The timer program-
ming happens in the menu B615-TIMERELAYS.
- Parking zone-1: always active / Timer-01 / Timer-02…. Timer-10
- Parking zone-2: always active / Timer-01 / Timer-02…. Timer-10
- .....
Also, you must put in, which floors are members of the parking zone. The way it is, you must put in the
lowest floor and the highest floor of the parking zone. If the parking zone only has one floor, you must
put in the same value in the lowest and highest floor.
e.g.:
- Parking zone-1: lowest floor: 02
- Parking zone-1: highest floor: 04
- …
Function:
If there is no elevator in the parking zone, then the next free elevator which has no travel,
will drive into the parking zone and will wait until there is a call. If an elevator has an active function
Praking Travel, then it cannot choose for the function Parking Zone. This elevator will drive to his Park-
ing Floor, if it has no calls.
The door-constellation (open or closed) will be changed in the menu B606.
-
Bus- RJ-45 Blue RJ45
RJ45 Bus- RJ-45 Blue
333
Spezial Drive indicator A1, T1
Spezial Drive indicator A2, T2