2KA
1-3-85
U464
Setting: [Permit]
1. Select On or Off.
Initial setting: On
2. Press the OK key. The setting is set.
Setting: [Time Interval]
1. Change the setting value using the Left/Right Select keys.
2. Press the OK key. The value is set.
Setting: [Slp Period Calib]
1. Change the setting value using the Left/Right Select keys.
2. Press the OK key. The value is set.
Setting: [Permit Act(50pp)]
1. Select On or Off.
Initial setting: On
2. Press the OK key. The setting is set.
Setting: [Permit(On/SlpOut)]
1. Select On or Off.
Initial setting: On
2. Press the OK key. The setting is set.
Setting: [Permit(AP/NE)]
1. Select On or Off.
Initial setting: On
2. Press the OK key. The setting is set.
Maintenance
item No.
Description
Display Description
Off Turns calibration OFF
On Turns calibration ON
Display Description Setting range Initial setting
Count Setting the interval time of calibration 0 to 9999 (s) 480
Display Description Setting range Initial setting
Time(Min) Setting the standard time of sleep mode 0 to 480 (min) 60
Display Description
Off Disables permission to execute at continuously 50 pages
On Enables permission to execute at continuously 50 pages
Display Description
OFF Executes calibration regardless of fuser temperature at power-up or
recovery from auto sleep mode
ON
Executes calibration if fuser temperature is less than 50
C/122F at
power-up or recovery from auto sleep mode
Display Description
OFF Paper interval calibration at the time of calibration/near end after
toner feed is not carried out
ON Paper interval calibration at the time of calibration/near end after
toner feed is carried out