EasyManua.ls Logo

Lauterbach TRACE32-ICD - System.Option.BUS32: Use 32-Bit Data-Bus Mode; System.Option.CONFIG: Select RCW Configuration

Lauterbach TRACE32-ICD
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PPC600 Family Debugger | 36
©
1989-2022 Lauterbach
SYStem.Option.BUS32 Use 32-Bit data-bus mode
Default: OFF. Enable this option if the CPU is operated in the reduced 32-bit data bus width mode. This
mode is often used in designs with PPC603e processors.
SYStem.Option.CONFIG Select RCW configuration
For MPC82XX only. When SYStem.Option.BASE is set to AUTO, this setting defines if the RCW is read
from the location designated to the configuration master, or from one of the seven locations designated to
the configuration slaves. By default setting, the debugger will read from the configuration master location.
Format: SYStem.Option.BUS32 [ON | OFF]
Format: SYStem.Option.CONFIG [Master | Slave1..7]