Maintenance
LB Performance CB95 Broom5-16
Fuse Box Panel Fuse Box Panel
The electrical system is protected from overload
damage by fuses. If an electrical component fails to
operate, check the fuse panel rst to ensure that a fuse
has not “blown.” The panel is located on the right side
panel in the cab. See the following table for corre-
sponding fuse information. (Figure 5-12)
A blown fuse is an indication that there is an overload
that needs to be corrected. If you replace a fuse, but it
continues to blow, contact your authorized LB Perfor-
mance dealer.
Always replace a blown fuse with
the same rating as specied. Never replace with a
higher amperage rating. Damage to the electrical
system or re can occur from improper fuse
replacement.
Figure 5-12. Fuse Panel and Fuse Sizes
Dielectric GreaseDielectric Grease
Dielectric grease is a nonconductive, insulating com-
pound applied to electrical connectors. When applied
correctly, a high-quality dielectric grease displaces
debris and moisture in the connector. The proper appli-
cation of dielectric grease lls any gaps between pins
or in the connector which prevents debris and moisture
from creating corrosion of the electrical components.
Equipment damage can occur if using
low-quality, incompatible dielectric grease.
If not applied or incorrectly applied, corrosion can result
that causes rapid increase in resistance, intermittent
connections, overheating, and a variety of electrical
problems. Numerous electrical issues throughout the
machine can be avoided by the proper application and
use of dielectric grease.
Figure 5-13. Correct Application of Dielectric
Grease