55
Maintenance
LB Performance CB95 Broom 5-27
Replace BatteriesReplace Batteries
Batteries create explosive gases
when charging. DO NOT expose these gases to
sparks or open ame during maintenance. Always
perform battery service in a well-ventilated area or
outside. Serious injury can occur from exploding
batteries.
1. Remove the black ground (-) cable from the
negative (-) battery terminal, followed by the red (+)
cable from the positive (+) battery terminal. (Figure
5-26)
Battery
Master
Switch
Figure 5-26. Battery System
If the negative cable is grounded
during removal, sparks will not occur. If the positive
cable is grounded during removal, sparks will occur
and could ignite explosive gases.
2. Remove the hold down bar.
3. Inspect the batteries for cracks, wear and damage
that could result in leaks.
4. Carefully remove the batteries from the battery
plate, noting battery position during removal.
DO NOT dry batteries using
compressed air. Allow the batteries and surrounding
area to dry. Battery acid can cause severe injury if
blown into the face or other areas of the body. If injury
occurs, seek medical attention immediately. Flush
eyes and skin for 30 minutes with clean water.
5. Make sure the battery cells are sealed. Clean the
batteries, battery tray, cables, and brackets with
baking soda and warm water. Allow to air dry.
6. Place the batteries in proper position in the battery tray.
7. Install hold down bar. Tighten bar to retain battery,
but not so tight as to damage battery.
When installing batteries, always
install the positive cable rst followed by the
negative cable. Reversed polarity can damage the
electrical system.
8. Install red (+) battery cable to the positive (+) battery
terminal.
9. Install the black (-) battery cable to the negative (-)
battery terminal.
10. Reattach the battery box cover and reconnect the
battery box locks.