UserResponse
Completethefollowingsteps:
1.Performtheactionsmentionedoneatatimeandtrythetestaftereachaction.
2.Iftheproblemremains,contactyourtechnical-servicerepresentative.
3.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.ReseatDIMM(s).
Reconnectittopower.
4.MakesurethatDSAandBIOS/uEFIareatthelatestlevel.
5.ReplaceanyDIMMS(s)mentionedinerror,onebyone.
6.MakesurethatallDIMMsareenabledintheConfiguration/SetupUtilityprogram.
7.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
201-901-002:StandaloneMemoryTestFailed
MemoryDiagnosticsTestFailed.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Performtheactionsmentionedoneatatimeandtrythetestaftereachaction.
2.Iftheproblemremains,contactyourtechnical-servicerepresentative.
3.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.ReseatDIMM(s).
Reconnectittopower.
4.MakesurethatDSAandBIOS/uEFIareatthelatestlevel.
5.ReplaceanyDIMMS(s)mentionedinerror,onebyone.
6.MakesurethatallDIMMsareenabledintheConfiguration/SetupUtilityprogram.
7.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
AppendixC.DSAdiagnostictestresults1109