Lenovo System x3500 M4 - Service Bulletins; Checkout Procedure; About the Checkout Procedure

Lenovo System x3500 M4
1182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Servicebulletins
Lenovocontinuallyupdatesthesupportwebsitewiththelatesttipsandtechniquesthatyoucanusetosolve
problemthatyoumighthavewiththeLenovoSystemx3500M4server.
TofindservicebulletinsthatareavailablefortheLenovoSystemx3500M4server,goto
http://www.lenovo.com/supportandsearchfor7383,andretain.
Checkoutprocedure
Thecheckoutprocedureisthesequenceoftasksthatyoushouldfollowtodiagnoseaproblemintheserver.
Aboutthecheckoutprocedure
Beforeyouperformthecheckoutprocedurefordiagnosinghardwareproblems,reviewthefollowing
information.
Readthesafetyinformationthatbeginsin“Safety”onpagev.
LenovoDynamicSystemAnalysis(DSA)providestheprimarymethodsoftestingthemajorcomponents
oftheserver,suchasthesystemboard,Ethernetcontroller,keyboard,mouse(pointingdevice),serial
ports,andharddiskdrives.Youcanalsousethemtotestsomeexternaldevices.Ifyouarenotsure
whetheraproblemiscausedbythehardwareorbythesoftware,youcanusethediagnosticprogramsto
confirmthatthehardwareisworkingcorrectly.
WhenyourunDSA,asingleproblemmightcausemorethanoneerrormessage.Whenthishappens,
correctthecauseofthefirsterrormessage.Theothererrormessagesusuallywillnotoccurthenext
timeyourunDSA.
Important:IfmultipleerrorcodesororlightpathdiagnosticsLEDsindicateamicroprocessorerror,the
errormightbeinthemicroprocessororinthemicroprocessorsocket.See“Microprocessorproblems”on
page152
forinformationaboutdiagnosingmicroprocessorproblems.
BeforeyourunDSA,youmustdeterminewhetherthefailingserverispartofasharedharddiskdrive
cluster(twoormoreserverssharingexternalstoragedevices).Ifitispartofacluster,youcanrunall
diagnosticprogramsexcepttheonesthattestthestorageunit(thatis,aharddiskdriveinthestorage
unit)orthestorageadapterthatisattachedtothestorageunit.Thefailingservermightbepartofa
clusterifanyofthefollowingconditionsistrue:
Youhaveidentifiedthefailingserveraspartofacluster(twoormoreserverssharingexternalstorage
devices).
Oneormoreexternalstorageunitsareattachedtothefailingserverandatleastoneoftheattached
storageunitsisalsoattachedtoanotherserverorunidentifiabledevice.
Oneormoreserversarelocatednearthefailingserver.
Important:Iftheserverispartofasharedharddiskdrivecluster,runonetestatatime.Donotrun
anysuiteoftests,suchasquick”or“normal”tests,becausethismightenabletheharddiskdrive
diagnostictests.
IftheserverishaltedandaPOSTerrorcodeisdisplayed,seeAppendixB“UEFI(POST)errorcodes”on
page965.Iftheserverishaltedandnoerrormessageisdisplayed,see“Troubleshootingbysymptom”
onpage147and“Solvingundeterminedproblems”onpage161.
Forinformationaboutpower-supplyproblems,see“Solvingpowerproblems”onpage160
,“Power
problems”onpage155,and“Power-supplyLEDs”onpage139.
Forintermittentproblems,checktheeventlog;see“Eventlogs”onpage141andAppendixC“DSA
diagnostictestresults”onpage989.
130Systemx3500M4InstallationandServiceGuide